5 - 110
Chapter 5 Data Used for Positioning Control
Item
Setting value
Default
value
Buffer memory address
Value set with GX Works2 Value set with sequence program
QD77MS2
QD77MS4
QD77MS16
Simultaneously starting axis
[Da.23]
Number of
simultaneously
starting axes
QD77MS16
2: 2 axes 2H
Da.24Da.26 Da.25Da.23
b0b4b8b12b15
0000H
22101+400n
3: 3 axes
3H
4: 4 axes 4H
[Da.24]
Simultaneously
starting axis No.1
QD77MS16
0: Axis 1 selected
1: Axis 2 selected
2: Axis 3 selected
3: Axis 4 selected
4: Axis 5 selected
5: Axis 6 selected
6: Axis 7 selected
7: Axis 8 selected
8: Axis 9 selected
9: Axis 10 selected
A: Axis 11 selected
B: Axis 12 selected
C: Axis 13 selected
D: Axis 14 selected
E: Axis 15 selected
F: Axis 16 selected
0H
1H
2H
3H
4H
5H
6H
7H
8H
9H
AH
BH
CH
DH
EH
FH
[Da.25]
Simultaneously
starting axis No.2
QD77MS16
[Da.26]
Simultaneously
starting axis No.3
QD77MS16
n: Axis No.-1