4 - 16
Chapter 4 Installation, Wiring and Maintenance of the Product
(4) Twisting
If the SSCNET cable is twisted, it will become the same stress added
condition as when local lateral pressure or bend is added. Consequently,
transmission loss increases, and the breakage of SSCNET
cable may
occur at worst.
(5) Disposal
When incinerating optical cable (cord) used for SSCNET cable,
hydrogen fluoride gas or hydrogen chloride gas which is corrosive and
harmful may be generated. For disposal of SSCNET
cable, request for
specialized industrial waste disposal services that have incineration facility
for disposing hydrogen fluoride gas or hydrogen chloride gas.
(6) Wiring process of SSCNET cable
Put the SSCNET cable in the duct or fix the cable at the closest part to
the Simple Motion module with bundle material in order to prevent
SSCNET
cable from putting its own weight on SSCNET connector.
Leave the following space for wiring.
• Putting in the duct
70mm
(2.76inch)
or more
5mm (0.20inch)
or more
Panel
98mm
(3.86inch)
30mm
(1.18inch)
or more
(Note-1)
80mm
(3.15inch)
or more
5mm (0.20inch)
or more
(Note-2)
Top of panel or wiring duct
QD77MS
Base unit
Door
(Note-1): For wiring duct with 50mm (1.97inch) or less height. For other cases, 40mm (1.58inch) or more.
(Note-2): 20mm (0.79inch) or more when the adjacent module is not removed and the extension cable is connected.