6 - 35
Chapter 6 Sequence Program Used for Positioning Control
MOVP H0 D73
*<Setting of normal start >
SM402
ON for 1
scan onl
y after
RUN
Point 1
*<Setting of normal start >
MOVP H0 D74
Point 2
*<Setting of normal start >
MOVP H0 D75
Point 3
*<Setting of normal start >
MOVP H0 D76
Point 4
*<Setting of normal start >
MOVP H0 D77
Point 5
TOP H0 K5D73
Point 1
K26050
*
*<Special start instruction to normal start >
*
*<Setting block start data to QD77 >
TOP H0 K5D68
Point 1
K26000
*<Setting block start data to QD77 >
651