The following example shows the show running-config interface command.
Dell#show running-config interface tengigabitethernet 1/16
!
interface TenGigabitEthernet 1/16
no ip address
mtu 9252
ip mtu 9234
switchport
sflow enable
sflow sample-rate 8192
no shutdown
Displaying Show sFlow on a Line Card
To view sFlow statistics on a specified line card, use the following command.
Display sFlow configuration information and statistics on the specified interface.
EXEC mode
show sflow linecard slot-number
Example of Viewing sFlow Configuration (Line Card)
Dell#show sflow linecard 1
Linecard 1
Samples rcvd from h/w :165
Samples dropped for sub-sampling :69
Total UDP packets exported :77
UDP packets exported via RP :77
UDP packets dropped :
Configuring Specify Collectors
The sflow collector command allows identification of sFlow collectors to which sFlow datagrams are
forwarded.
You can specify up to two sFlow collectors. If you specify two collectors, the samples are sent to both.
Identify sFlow collectors to which sFlow datagrams are forwarded.
CONFIGURATION mode
sflow collector ip-address agent-addr ip-address [number [max-datagram-size
number] ] | [max-datagram-size number ]
The default UDP port is 6343.
The default max-datagram-size is 1400.
Changing the Polling Intervals
The sflow polling-interval command configures the polling interval for an interface in the
maximum number of seconds between successive samples of counters sent to the collector.
This command changes the global default counter polling (20 seconds) interval. You can configure an
interface to use a different polling interval.
To configure the polling intervals globally (in CONFIGURATION mode) or by interface (in INTERFACE
mode), use the following command.
840
sFlow