QSFP 168 BR max = 0
QSFP 168 BR min = 0
QSFP 168 Vendor SN = Z12I00005
QSFP 168 Datecode = 130117
QSFP 168 CheckCodeExt = 0xe8
QSFP 168 Diagnostic Information
===================================
QSFP 168 Rx Power measurement type = Average
===================================
QSFP 168 Temp High Alarm threshold = 80.000C
QSFP 168 Voltage High Alarm threshold = 3.630V
QSFP 168 Bias High Alarm threshold = 120.000mA
QSFP 168 RX Power High Alarm threshold = 2.138mW
QSFP 168 Temp Low Alarm threshold = -10.000C
QSFP 168 Voltage Low Alarm threshold = 2.970V
QSFP 168 Bias Low Alarm threshold = 5.000mA
QSFP 168 RX Power Low Alarm threshold = 0.017mW
===================================
QSFP 168 Temp High Warning threshold = 75.000C
QSFP 168 Voltage High Warning threshold = 3.465V
QSFP 168 Bias High Warning threshold = 100.000mA
QSFP 168 RX Power High Warning threshold = 1.698mW
QSFP 168 Temp Low Warning threshold = -5.000C
QSFP 168 Voltage Low Warning threshold = 3.135V
QSFP 168 Bias Low Warning threshold = 10.000mA
QSFP 168 RX Power Low Warning threshold = 0.043mW
===================================
QSFP 168 Temperature = 21.891C
QSFP 168 Voltage = 3.314V
QSFP 168 TX1 Bias Current = 0.000mA
QSFP 168 TX2 Bias Current = 0.000mA
QSFP 168 TX3 Bias Current = 0.000mA
QSFP 168 TX4 Bias Current = 0.000mA
QSFP 168 RX1 Power = 0.000mW
QSFP 168 RX2 Power = 0.000mW
QSFP 168 RX3 Power = 0.000mW
QSFP 168 RX4 Power = 0.000mW
Recognize an Over-Temperature Condition
An alarm message is generated and displayed when an over-temperature condition on a system
component occurs. Either a minor or a major alarm is triggered.
A minor temperature alarm is displayed when any system temperature threshold is exceeded. In this case,
the system fan speed is gradually increased to 60% duty cycle (PWM). If the sensor’s temperature does
not decrease, the system fan speed is increased to a 70% duty cycle (PWM) and a major over-temperature
alarm is generated.
Over-temperature alarms are logged. Use the show alarms command to display the currently logged
alarms.
To display the pre-configured sensor thresholds, use the show alarms threshold command.
Dell#show alarms threshold
-- System Core --
-- Temperature Limits (deg C) --
---------------------------------------------------------------------------
308