Dell 9.7(0.0) Plumbing Product User Manual


  Open as PDF
of 1039
 
+ HG Link Status Test for Fabric 3: PASSED
+ HG Link Status Test for Fabric 4: PASSED
+ HG Link Status Test for Fabric 5: PASSED
fabricLinkStatusTest ........................................ PASS
Starting test: fanTest ......
ERROR: Tray[0] fan[1] speed 49% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[0]
ERROR: Tray[1] fan[0] speed 49% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[1]
+Fan tray[2] Speed test PASS
+Fan tray[3] Speed test PASS
ERROR: Tray[4] fan[0] speed 49% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[4]
fanTest ..................................................... FAIL
i2cTest ..................................................... PASS
macPhyRegTest ............................................... PASS
Starting test: partyLinkStatusTest ......
WM0 Link Status UP
partyLinkStatusTest ......................................... PASS
Starting test: pcieRwTest ......
PCIe Read/Write Test for Vendor ID = 0x10ee device ID = 0x7011
PCIe Read/Write Test for Vendor ID = 0x14e4 device ID = 0xb636
pcieRwTest .................................................. PASS
rtcTest ..................................................... PASS
sataSsdTest ................................................. PASS
triumphLinkStatusTest ....................................... PASS
Starting test: usbTest ......
-USB "/dev/rsd0d" is not plugged/mounted/formatted; test SKIPPED
usbTest ..................................................... FAIL
--------- Group Test Statistics ---------
Total : 28
Passed : 25
Failed : 3
Elapsed time : 00H:03M:38S
Stop reason : after completion
------ Failed tests (level, times) ------
usbTest (0, 1)
fanTest (1, 1)
usbTest (1, 1)
LEVEL 2 DIAGNOSTIC
Starting test: triumphFabricTrafficTest ......
Triumph port 7 to Fabric traffic test PASSED
Triumph port 8 to Fabric traffic test PASSED
Triumph port 9 to Fabric traffic test PASSED
Triumph port 10 to Fabric traffic test PASSED
Triumph port 11 to Fabric traffic test PASSED
Triumph port 12 to Fabric traffic test PASSED
triumphFabricTrafficTest .................................... PASS
--------- Group Test Statistics ---------
Total : 26
Passed : 25
Failed : 1
Elapsed time : 00H:05M:21S
Stop reason : after completion
------ Failed tests (level, times) ------ psuTest (0, 1)
Sample Test Log for Line-Card CPU: TestReport-LP-0.txt
Example of a Test Log for Line-Card CPU 0: TestReport-LP-0.txt
Dell#show file flash://TestReport-LP-0.txt
Debugging and Diagnostics
299