Chapter 13 Control Sub Functions
[2] Precautions during control
(1) A command in-position width check will not be carried out in the following
cases.
During speed control
During speed control in speed-position switching control
During speed control in position-speed switching control
During speed control mode
During torque control mode
During continuous operation to torque control mode
Command in-position flag
( Md. 31 Status: b2)
Speed to position switching
t
Positioning
control start
Speed-position
switching
control start
Command in-position
width setting value
V
Execution of the command in-position width check
OFF
ON
Command in-position
width setting value
Execution of the command in-position
width check
Fig. 13.44 Command in-position width check
(2) The command in-position flag will be turned OFF in the following cases.
("0" will be stored in "[Md.31] Status: b2".)
At the positioning control start
At the speed control start
At the speed-position switching control, position-speed switching control
start
At the OPR control start
At the JOG operation start
At the inching operation start
When the manual pulse generator operation is enabled
(3) The "[Pr.16] Command in-position width" and command in-position flag
([Md.31] Status: b2) of the reference axis are used during interpolation
control.
When the "[Pr.20] Interpolation speed designation method" is "Composite
speed", the command in-position width check is carried out in the remaining
distance on the composite axis (line/arc connecting the start point address
and end point address).