5 - 172
Chapter 5 Data Used for Positioning Control
Setting item Setting details
[Cd.16] Inching movement amount
Use this data item to set the amount of movement by inching.
The machine performs a JOG operation if "0" is set.
Set a value within the following range:
[Pr.1] Unit
setting
mm
(
10
-1
µm)
inch
(
10
-5
inch)
degree
(
10
-5
degree)
PLS
(PLS)
Setting range 0 to 65535 0 to 65535 0 to 65535 0 to 65535
Fetch cycle: At start
[Cd.17] JOG speed
Use this data item to set the JOG speed.
Set a value within the following range:
[Pr.1] Unit
setting
mm
(
10
-2
mm/min)
inch
(
10
-3
inch/min)
degree
(
10
-3
degree/min)
PLS
(PLS/s)
Setting range
1 to
2000000000
1 to
2000000000
1 to
2000000000
1 to 1000000000
: When "[Pr.83] Speed control 10 x multiplier setting for degree axis" is valid,
this will be the setting range 1 to 2000000000 (
10
-2
degree/min).
Fetch cycle: At start
[Cd.18] Interrupt request during
continuous operation
To interrupt a continuous operation, set "1" to this data item.
After processing the interruption request ("1"), the Simple Motion module
automatically resets the value to "0".
Fetch cycle: Operation cycle