5 - 150
Chapter 5 Data Used for Positioning Control
Storage item Storage details
[Md.109] Regenerative load ratio/
Optional data monitor output
1
The rate of regenerative power to the allowable regenerative power is indicated
as a percentage.
When the regenerative option is used, the rate to the allowable regenerative
power of the option is indicated.
(Buffer memory) %
This area stores the content set in "[Pr.91] Optional data monitor: Data type
setting 1" at optional data monitor data type setting.
Refresh cycle: Operation cycle
[Md.110] Effective load torque/
Optional data monitor output
2
The continuous effective load torque is indicated.
The average value of the load rates for the past 15 seconds to the rated torque is
stored as a percentage, rated torque being 100%.
(Buffer memory) %
This area stores the content set in "[Pr.92] Optional data monitor: Data type
setting 2" at optional data monitor data type setting.
Refresh cycle: Operation cycle
[Md.111] Peak torque ratio/
Optional data monitor output
3
The maximum torque is indicated. (Holding value)
The peak values for the past 15 seconds are indicated, rated torque being 100%.
(Buffer memory) %
This area stores the content set in "[Pr.93] Optional data monitor: Data type
setting 3" at optional data monitor data type setting.
Refresh cycle: Operation cycle
[Md.112] Optional data monitor output
4
This area stores the content set in "[Pr.94] Optional data monitor: Data type
setting 4" at optional data monitor data type setting. ("0" is stored when the
optional data monitor data type is not set.)
Refresh cycle: Operation cycle
[Md.113] Semi/Fully closed loop
status
The switching status of semi closed loop control/fully closed loop control is
indicated.
Refresh cycle: Operation cycle
[Md.114] Servo alarm
This area stores the servo alarm code and servo warning code displayed in LED
of servo amplifier.
When the "[Cd.5]
A
xis error reset" (axis control data) is set to ON after remove the
error factor of servo amplifier side, the servo alarm is cleared (set to 0).
Refresh cycle: Immediate