Omron V022-E3-1 Thermostat User Manual


 
Automatic Reset
Data Bit Length
Stop Bit Length
ON
7bits
Parity Bit
Flow Control
2bits
Odd
XON/XOFF
[ MEMORY SWITCH MENU (2/2) ]
RS-232C Speed 19200bps
EXIT
SAVE
EXIT
PREV.
PAGE
[ SYSTEM MENU ]
Quit
Transmit Mode
Maintenance Mode
[ MAINTENANCE MENU ]
Quit
PT Setting Status
I/O Check
Display History
Memory I ni t.
Memory Swi tches

Section 3-6
RS-232C method
Automatic Reset Selecting the Automatic Reset Function (page 90)
Host Link Speed Selecting the Host Link Communication Speed (page 86)
PT UNIT No. Setting the PT UNIT No. (page 87)
Data Bit Length Setting the RS-232C Communication Conditions (page 89)
Stop Bit Length Setting the RS-232C Communication Conditions (page 89)
Parity Bit Setting the RS-232C Communication Conditions (page 89)
Flow Control Setting the RS-232C Communication Conditions (page 89)
RS-232C Speed Setting the RS-232C Communication Conditions (page 89)
4-6-1 Selecting the Host Communication Method
The NT600S can be connected to a PC/Host by the host link, NT link (1:1, 1:N),
C200H direct, or RS-232C. Either link can be selected by setting the “Comm.
Method” memory switch. The factory setting has been made to the “Host link”.
Select the host communication method by the menu operation from the System
Menu as mentioned below.
Select “Maintenance Mode”.
Select “Memory Switches”.