Section 4-6
Guide display message
Lamps can be displayed with the guide display messages.
➡ The guide display message attributes are the same as that for the “character
display”. Refer to “Characters and Figures which can be Displayed” (page
128).
Frame and lit/flashing
The display method of “lit/flashing” varies according to the frame setting.
Frame is set: Only the area in the frame will be lit/flashing.
Frame is not set: The area including the frame will be lit/flashing.
[Frame is set]
Unlit
Flash
Lit
Area inside the frame
flashes.
Area including the frame
flashes.
[Frame is not set]
Unlit
Flash
Lit
Controlling lamps in a batch
Multiple lamps can be lit or flashed in a batch by registering multiple lamp alloca-
tions to the same screen.
[Example of batch lighting]
Set the same bit number or lamp number for lamps L1 to L5.
L1
L2
L3
L4 L5
L1 L2 L3
L4