Omron V022-E3-1 Thermostat User Manual


 
Reference

Section 6-2
Bit ON: The lamp or touch switch is turned on (or caused to flash).
Bit OFF: The lamp or touch switch is turned off.
Example To turn on lamps and touch switches with the numbers 1, 5, 6, 7, and 26
m0
1
m0
2
m1
1
m1
2
m2
1
m2
2
m3
1
m3
2
m13
1
m13
2
=
E200000400000000000000000000
Description Changes the display status of the lamps or touch switches.
Whether the lamp or touch switch which corresponds to the specified bit is
turned on or flashes is determined by the setting made using the support tool.
Lamp and Touch Switch Display (Number Specification)
Format
1B
[ESC]
n
1
n
2
m
1
51
Q
n
3
m
1
: Display status
m
1
Display Status
0(30
H
) Not lit (normal display)
1(31
H
) Lit
2(32
H
) Flashing inverse
3(33
H
) All not lit
n
1
n
2
n
3
: Lamp or touch switch address (3-digit hexadecimal)
000 to 0FF
H
(0 to 255)
Description Changes the lamp or touch switch lighting status.
Specify the display status as 3 (all not lit) to turn off all the lamps and touch
switches. In this case, specify the lamp or touch switch number to any number in
the permitted range.
The display attributes set with the Support Tool determine if lamps #0 to #111 light
continuously or flash. The display status set with this command is ignored.
Enquiry of the Display Status Use the following command to enquire whether a lamp or touch switch is displayed
continuously lit or flashing by specifying its number.
Lamp and Touch Switch Display Status Enquiry
Format
1B
[ESC]
n
1
n
2
52
R
n
3
n
1
n
2
n
3
: Lamp or touch switch address (3-digit hexadecimal)
000 to 0FF
H
(0 to 255)