Omron V022-E3-1 Thermostat User Manual


 
Reference

Section 6-2
Copying the Memory Table Use the following command to change numerals or character-strings to be dis-
played on the NT600S after copying the contents of a memory table.
Copy Memory Table
Format
1B
[ESC]
s
1
s
2
d
1
d
2
d
3
m
1
s
3
2F
/
m
1
: Type of memory table
0(30
H
): Character-string memory table
1(31
H
): Numeral memory table
s
1
s
2
s
3
: Copy source memory table address (see table below)
d
1
d
2
d
3
: Copy destination memory table address (see table below)
Character-string
memory table address
Numeral memory table address
000 to 255 (3-digit BCD) 000 to 511 (3-digit BCD)
Description Copies the contents of the copy source memory table to the copy destination
memory table. The memory table contents are copied to a memory table of the
same type: character-string memory table tocharacter-string memory table or nu-
meral table to numeral memory table.
Operation 1. Register the memory table - which contains the numerals or character-string
to be displayed - for the screen when creating the screen data using the sup-
port tool.
In the case of a character-string, use the “character-string display” mode of the
support tool to specify the character-string memory table.
In the case of a numeral, use the “numeral display” mode of the support tool to
specify the numeral memory table.
2. Whencreating the screen data using the support tool, set the copy sourcedata
in the memory table.
Use the “table edit” mode.
This method can be conveniently used to switch the numeral or character-string
display according to the operating status. If several sets of copy source data are
prepared in advance, it is possible to display the data that matches the operating
status.