Omron FQM1-CM001 Home Security System User Manual


 
75
Wiring Servo Relay Units Section 3-4
Applicable Connector-Terminal Block Conversion Units
Recommended Wire
Size
The recommended size for cable wires is AWG24 to AWG26 (0.2 to
0.13 mm
2
). Use a cable with an outer diameter of less than 1.61 mm.
3-4 Wiring Servo Relay Units
XW2B-80J7-1A Servo Relay Units can be used to connect Motion Control
Modules and Servo Drivers.
A Servo Relay Unit simplifies wiring, e.g., from a Motion Control Module to
two Servo Drivers, for general-purpose I/O wiring, such as for switches and
sensors, and for RS-422A line wiring.
The Servo Relay Unit uses a special cable and simplifies connections from
one Motion Control Module to two Servo Drivers, such as the W Series and
SMARTSTEP Series.
Servo Relay Units can be mounted to DIN Track or on the panel itself.
Connecting Cable Connector-Terminal Block
Conversion Unit
Number of
pins
Size
XW2Z-@@@K XW2D-40G6 40 pins Miniature
XW2B-40G5 Standard
XW2B-40G4 Standard
XW2Z-@@@J-A28 XW2D-34G6 34 pins Miniature
INC
servo1
ABS _CW-
0
19