Omron FQM1-CM001 Home Security System User Manual


 
323
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations Appendix C
CX-Programmer: Pulse Output Tab Page
+323 00 to 03 High-speed
counter 2 (Counter
2)
Input method Same as for high-speed counter 1 except that fre-
quency measurement (Counter data to monitor,
bit 00 to 03 of +324: 02 hex) cannot be set for
high-speed counter 2.
At power ON
04 to 07 Reset method
08 to 11 Counting speed
12 to 15 Counter operating
mode (Counter opera-
tion)
+324 00 to 03 Counter data to moni-
tor (Counter data dis-
play)
04 to 15 Reserved
+325 00 to 15 Sampling time (for
mode 1 only)
+326 to 327 00 to 15 High-speed
counter 1 (Counter
1)
Circular maximum
count
Sets the maximum circular counter value.
Range: 0000 0001 to FFFF FFFF hex
Absolute encoder res-
olution
0000 0001 to 0000 FFFF hex
Note Set this value in pulses/rotation according
to the encoder dividing ratio set for the Servo
Driver and the input method multiplier set for the
Module.
Example: If the Servo Driver setting is 1,000 and
the Module setting is x4, set FA0 (4,000).
+328 to 329 00 to 15 High-speed
counter 2 (Counter
2)
Circular maximum
count
Same as for high-speed counter 1.
Absolute encoder res-
olution
+330 to 331 00 to 15 High-speed
counter 1 (Counter
1)
Absolute offset 8000 0000 to 7FFF FFFF hex
+332 to 333 00 to 15 High-speed
counter 2 (Counter
2)
Absolute offset 8000 0000 to 7FFF FFFF hex
Address Bits Function Remarks When setting is
read
+340 00 to 07 Pulse output 1 Operation mode
(Refer to 7-6-6
Pulse Output
Function Details.)
00 hex: Relative pulse output
01 hex: Absolute pulse output in linear mode
02 hex: Absolute pulse output in circular mode (See
note.)
03 hex: Electronic cam control in linear mode (See
note.)
04 hex: One-shot pulse output
05 hex: Time measurement using pulse counter
06 hex: Electronic cam control in circular mode (See
note.)
At power ON
08 to 15 Clock 00 hex: 20 MHz Pulse output frequency: 400 Hz
to 1 MHz
01 hex: 10 MHz Pulse output frequency: 200 Hz
to 200 kHz
02 hex: 5 MHz Pulse output frequency: 100 Hz
to 100 kHz
03 hex: 2.5 MHz Pulse output frequency: 40 Hz
to 50 kHz
04 hex: 1.25 MHz Pulse output frequency: 20 Hz
to 20 kHz
+341 00 to 07 Pulse output 2 Operation mode Same as for pulse output 1.
08 to 15 Clock
+342 to 343 00 to 15 Pulse output 1 Circular maximum
count
Sets the maximum circular counter value when the
pulse output mode is set to absolute pulse output in
circular mode or electronic cam control in circular
mode.
Range: 0000 0001 to FFFF FFFF hex (See note.)
+344 to
+345
00 to 15 Pulse output 2 Circular maximum
count
Same as for pulse output 1.
Address Bits Function Remarks When setting is
read