Pulse Outputs Section 7-6
Indepen-
dent
mode
(Position-
ing)
Pulse output
starts at the
specified fre-
quency and
stops when the
specified num-
ber of pulses
have been out-
put.
(The number of
pulses cannot
be changed dur-
ing pulse out-
put.)
PULS(88
6)
SPED(88
5)
No. of
pulses,
Relative or
absolute
operation,
Port,
CW/CCW,
Indepen-
dent,
Target fre-
quency
Use when
positioning
with a sin-
gle-phase
output and no
acceleration
or decelera-
tion. (See
page 189.)
The frequency
accelerates or
decelerates at a
fixed rate and
stops immedi-
ately when the
specified num-
ber of pulses
have been out-
put.
(The number of
pulses cannot
be changed dur-
ing pulse out-
put.)
PULS(88
6)
ACC(888)
No. of
pulses,
Relative or
absolute
operation,
Port,
CW/CCW,
Indepen-
dent,
Accelera-
tion/decel-
eration
rate,
Target fre-
quency
---
Pulse output
starts at the
specified fre-
quency and
stops immedi-
ately when the
specified posi-
tion is reached.
(The target posi-
tion can be
changed during
positioning
(pulse output).)
PULS(88
6) (Elec-
tronic
Cam Con-
trol)
Port,
Target fre-
quency,
Absolute
positioning
Use for abso-
lute position-
ing
(electronic
cam control)
with a sin-
gle-phase
output, no
acceleration
or decelera-
tion, and tar-
get position
changes in a
fixed time
interval. (See
page 191.)
The frequency
accelerates at a
fixed rate, decel-
erates at a fixed
rate, and stops
when the speci-
fied number of
pulses have
been output.
(The number of
pulses cannot
be changed dur-
ing positioning
(pulse output).)
PLS2(887
)
Port,
CW/CCW,
Accelera-
tion rate,
Decelera-
tion rate,
Target fre-
quency,
Starting
frequency,
No. of
pulses
Use for trape-
zoidal accel-
eration/
deceleration
within a set
time (the
dwell time)
and then a
repeat of the
operation in
the opposite
direction.
(See
page 193.)
Mode Frequency changes Description Procedure Example
Instruc-
tions
Settings
Frequency
Target
frequency
SPED executed.
Tim
e
Specified no. of pulses
(Specified with PULS)
Stops after specified no.
of
p
ulses are out
p
ut.
Frequency
Target
frequency
ACC executed.
Tim
e
Specified no. of pulses
(Specified with PULS)
Stops after specified no.
of
p
ulses are out
p
ut.
Acceleration
rate
Frequency
Target
frequency
PULS executed.
Tim
e
Sto
p
s at s
p
ecified
p
osition.
Present
frequency
Frequency
Target
frequency
Output
starts
Time
Starting
frequency
Output
stops
Target
reached
Stopping
frequency
Deceleration
point
Acceler-
ation rate
Deceleration rate
Specified number
of pulses