228
Analog Outputs Section 7-10
Specified Output Values and Analog Output Signals
7-10-4 Applicable Instructions
END Refreshing Set the analog output values in A560 and A561 using an instruction such as
the MOV instruction.
With Immediate
Refreshing
Outputs can be controlled with SPED(885) and ACC(888) as outlined below.
SPED(885) can be used to change the output value in steps.
10 to 10 V
0 to 10 V
0 to 5 V 1 to 5 V
Analog output signal
Specified output value
(4-digit Hex)
Analog output signal
Specified output value
(4-digit Hex)
Analog output signal
Specified output value
(4-digit Hex)
Analog output signal
Specified output value
(4-digit Hex)
0000
0.0 V
0.5 V
10.0 V
10.5 V
0FA0
1068
FF38
Resolution: 4,000
10.0 V
11.0 V
+10.0 V
+11.0 V
157C
EA84
Resolution: 10,000
0000
0.0 V
0000
0.0 V
0.25 V
5.0 V
5.25 V
0FA0
1068
FF38
Resolution: 4,000
0000
1.0 V
0.8 V
5.0 V
5.2 V
0FA0
1068
FF38
Resolution: 4,000
EC78 1388
P: Port specifier
(#0001 for analog output 1 or #0002 for analog output 2)
F: Analog output value
M: Always #0000
(@) SPED
P
#0000
F