Omron FQM1-CM001 Home Security System User Manual


 
363
Auxiliary Area Allocations Appendix D
Note When a double-length operand is used, add 1 to the value shown in the length column in the above
table.
Sequence Control Instructions
Note When a double-length operand is used, add 1 to the value shown in the length column in the above
table.
Timer and Counter Instructions
Note When a double-length operand is used, add 1 to the value shown in the length column in the above
table.
Comparison Instructions
Instruction Mnemonic Code Length
(steps)
(See
note.)
ON execution
time (
µs)
Hardware
implementation
Conditions
END END 001 1 7.0 Yes ---
NO OPERATION NOP 000 1 0.05 Yes ---
INTERLOCK IL 002 1 0.15 Yes ---
INTERLOCK CLEAR ILC 003 1 0.15 Yes ---
JUMP JMP 004 2 0.95 Yes ---
JUMP END JME 005 2 --- --- ---
Instruction Mnemonic Code Length
(steps)
(See
note.)
ON execution
time (
µs)
Hardware
implementation
Conditions
TIMER TIM --- 3 1.30 Yes ---
COUNTER CNT --- 3 1.30 Yes ---
HIGH-SPEED TIMER TIMH 015 3 1.80 Yes ---
ONE-MS TIMER TMHH 540 3 1.75 Yes ---
REVERSIBLE
COUNTER
CNTR 012 3 24.8 --- ---
Instruction Mnemonic Code Length
(steps)
(See
note.)
ON execution
time (
µs)
Hardware
implementation
Conditions
Input Comparison
Instructions (unsigned)
LD, AND, OR += 300 4 0.35 Yes ---
LD, AND, OR + <> 305
LD, AND, OR + < 310
LD, AND, OR +<= 315
LD, AND, OR +> 320
LD, AND, OR +>= 325
Input Comparison
Instructions (double,
unsigned)
LD, AND, OR +=+L 301 4 0.35 Yes ---
LD, AND, OR +<>+L 306
LD, AND, OR +<+L 311
LD, AND, OR +<=+L 316
LD, AND, OR +>+L 321
LD, AND, OR +>=+L 326
Input Comparison
Instructions (signed)
LD, AND, OR +=+S 302 4 0.35 Yes ---
LD, AND, OR +<>+S 307
LD, AND, OR +<+S 312
LD, AND, OR +<=+S 317
LD, AND, OR +>+S 322
LD, AND, OR +>=+S 327