Omron FQM1-CM001 Home Security System User Manual


 
188
Pulse Outputs Section 7-6
Select pulse output 1 or 2.
2. Wire the output.
Output: CW and CCW
Output power supply: 5 V DC
3. Make the necessary System Setup settings (Pulse Output Tab Page
Op-
eration Mode).
Set the pulse output operation mode (in the Pulse Output Tab Page
Operation Mode) to relative pulse output or absolute linear pulse output.
Set the clock speed for pulse outputs 1 and 2.
4. Create the necessary ladder programming.
Use PLS2(887) to start pulse output control with trapezoidal acceleration/
deceleration from the specified port (acceleration and deceleration are
specified separately).
Use INI(880) to stop pulse output from the specified port.
Use PRV(881) to read the pulse output PV of the specified port.
One-shot Pulse Output (STIM(980))
1,2,3... 1. Determine pulse output port.
Select pulse output 1 or 2.
2. Wire the output.
3. Make the necessary System Setup settings.
Set the pulse output operation mode (in the Pulse Output Tab Page
Operation Mode) to 1 shot.
4. Create the necessary ladder programming.
Use STIM(980) (with C1 = #0001 or #0002) to turn ON the one-shot pulse
output.
Note The STIM(980) one-shot pulse output function can be used at the same time
as an STIM(980) timer interrupt function (one-shot timer or scheduled timer).
Pulse Counter Timer Function (STIM(980))
1,2,3... 1. Determine pulse output port.
Select pulse output 1 or 2.
2. Make the necessary System Setup settings.
INI
PLS2
PRV
A621 A620
A623 A622
A624
A625
CW
CCW
CW
CCW
Pulse output
port 1
Pulse output
port 2
Single-phase pulse output
with trapezoidal
acceleration/deceleration
Start
output
Ladder program Ladder program
Stop pulse output.
Set number of output pulses.
Target frequency: 20 Hz to 1 MHz
Acceleration/deceleration rates
(set separately)(1 or 2 ms cycle,
1 Hz to 9,999 Hz)
Start pulse output.
Pulse output
mode
System Setup
Mode settings for
ports 1 and 2
Port 1
Port 2
Port 1
Port 2
Refresh status (once each cycle
just after instruction execution)
Pulse output status
Pulse output PV
Refresh PV (once each cycle) Refresh PV (immediate refresh)
Read pulse output PV
Starting frequency: 0 Hz to 1 MHz
HIGH-SPEED
COUNTER
PV READ
MODE CONTROL
PULSE
OUTPUT