Pulse Outputs Section 7-6
7-6-5 Applicable Instructions
The following seven instructions can be used to control pulse outputs. The
relationship between the instruction and the types of pulse output that is pos-
sible is also listed in the following table.
Instructions Ineffective
during Pulse Output
Once pulse output has been started by an instruction, the output cannot
always be changed with an instruction. Refer to 7-6-15 Pulse Output Starting
Conditions for details on the allowed combinations of pulse output instruc-
tions.
Instruction Control Positioning (Independent Mode) Speed Control (Continuous
Mode)
No
acceleration/
deceleration,
single-phase
output
Acceleration/deceleration,
single-phase output
No
acceleration/
deceleration,
single-phase
output
Acceleration/
deceleration,
single-phase
output
No trapezoid,
acceleration
and
deceleration
Trapezoid,
separate
acceleration and
deceleration rates
PULS(886) Sets number of out-
put pulses or abso-
lute position.
OK OK No No No
SPED(885) Controls pulse out-
put without acceler-
ation or
deceleration (num-
ber of pulses set
with PULS(886) for
positioning).
OK No No OK No
ACC(888) Controls pulse out-
put with same
acceleration and
deceleration with-
out trapezoid (num-
ber of pulses set
with PULS(886) for
positioning).
No OK No No OK
PULS(886)
for Elec-
tronic Cam
Sets absolute posi-
tion or frequency
and outputs pulses.
OK No No No No
PLS2(887) Controls pulse out-
put with different
acceleration and
deceleration with
trapezoid (number
of pulses is also set
using PLS2(887)).
No No OK No No
INI(880) Stops pulse output. OK OK OK OK OK
PRV(881) Reads the current
PV for pulse output.
OK OK OK OK OK