Barco R9843501 Pet Fence User Manual


 
8. Getting started
8.6.2.1 Dening Acuras 1-point position
Acuras 1-point
In case of 1-point position, one single reference point per channel will be dened as reference point. At this point the automatic
color and brightness measurements for that channel are performed. A good practice is to choose the center of the visible part of the
image of the selected channel as reference point. The laser pointer is used to aim the spectrometer to the desired reference point.
Since the laser pointer is installed next to the spectrometer, there will be a small parallax error between the
laser pointer and t he spectrometer F ield o f View, d epen ding o n the dis tance to these d evices.
If you have dened multiple H ead Location in the Options page, then physically position your AutoAlignment
Head at the co rrect head location in the d isplay p rior to d ening a Acuras 1-point position.
How to dene the reference point in case of Acuras 1-point posi tion?
1. Project any image or internal pattern.
2. On the Positioning Page, navigate to P osition > Position type and select Acuras 1-point from the drop down list.
Image 8-20
Position type: Acuras 1-point
3. Press the New buttontodene a new position or select an existing position from Position drop down list to change it. For a new
position, a name must be entered in the Position edit box.
R59770509 AUTOALIGNMENT HEAD GEN II 26/11/2013
57