9. Dynacolor™ calibration
Image 9-3
Applying the measured value
Note: The x and y coordinates and L values of the selected projector are up dated in the Des ired values section automatically.
See image 9-3.
Message “Inconsistent data”
After Dynacolor calibration, it can happen that an error message pops up. If the sum of the L values of Red, Green and Blue does
not equal the L value of White in the measured values, the error message Inconsistent data appears. This can be caused by one
of the following situations:
• There was toomuchambientlightor stray light during the measurement. Redo the measurement after all ambient light has
been turned off.
• CLO was active during the measurement. CLO mus t be tur ned off prior to starting the Dynacolor calibration.
• Too much lamp flicker during the calibration. Try again. If the problem persists, lamp replacement is advised.
9.2 Matching Dynacolor sets of multiple projectors
Matching Dynacolor s ets is performed by the Optimize function (See Optimize button on the Dyn acolor page
in the X DS RACU user interface).
Matching Dynacolor sets is used to match the Dynacolor sets o f mu ltiple projectors or to match L eft eye and
Right eye set in one single stereo projector.
Make su re that Acuras position(s) have been de fined for each projector of the selected group prior to running
the Dynacolor Optimize process.
How to match Dynacolor sets of multiple projectors?
1. Optionally, calibrate Dynacolor for one or more projectors of the group. See "Dynacolor calibration", page 107.
2. Select the group to be calibrated.
3. Select a projector in that group.
R59770509 AUTOALIGNMENT HEAD GEN II 26/11/2013
109