10. Operating Acuras
Image 10-16
Start Capture button
Caution: F ollowing warning message appears (see ) in the feedback w indow, if the calibration file of the spectrometer is
missing or doesn’t exist. In that c ase, upload the spectrometer calibration file to the correct location on the MCU (see
"Uploading the spectrometer calibration file", page 41) and restart the XDS RACU application followed b
yrestarting
the Acuras capture process.
Image 10-17
Feedback window: Spectrometer calibration file is missing
6. In the appearing A curas dialog,
-pressSelected G roup to run the Acuras capture process to all projectors of the selected group.
-pressSelected Projector to run the Acuras capture process to the selected projector(s) of the selected group.
-pressCan cel to abort the Acuras capture process.
Image 10-18
Acuras dialog
Note: The uns elected projector(s) and the projector(s) on which the Acuras c apture process is not running go to pause state.
Note: If different head locations were used during the definition of Acur as positions, the user will be prompted to move t he
AutoAlignment Head to the corresponding phy sical locations during the Acuras capture pr ocess.
Image 10-19
It may take a few minutes to complete the Acuras capture operation for each projector.
R59770509 AUTOALIGNMENT HEAD GEN II 26/11/2013