No.
Name Application
Detection setting of TREN1 signal
SW1 SW2
Dip switch 1
OFF OFF
ON ON
ON OFF
TREN is detected when
TREN signal turns off to on.
Dip switch 2
OFF ON
TREN is detected when TREN
signal turns on to off.
Detection setting of TREN2 signal
SW3 SW4
Dip switch 3
OFF OFF
ON ON
ON OFF
TREN is detected when
TREN signal turns off to on.
Dip switch 4
OFF ON
TREN is detected when TREN
signal turns on to off.
Detection setting of TREN3 signal
SW5 SW6
Dip switch 5
OFF OFF
ON ON
ON OFF
TREN is detected when
TREN signal turns off to on.
6)
Dip switches
(Note-1)(Note-2)
123456
ON
(Shipped from the
factory in OFF
position)
Dip switch 6
OFF ON
TREN is detected when TREN
signal turns on to off.
7) Module fixing hook Hook used to fix to the base unit.
(Note-1) : When using the Q173PX-S1 only.
(Note-2) : The function is different according to the operating system software installed.
POINTS
The lighting condition of input display LED is shown below.
(1) PLS.A 1 to 3, PLS.B 1 to 3
• Q173PX is set on the system setting display of SW6RN-GSV
P.
• All axes servo ON command (M2042) turned on.
• Manual pulse generator enable flag (M2051, M2052, M2053) turned on.
• Manual pulse generator signal is input.
(2) TREN 1 to 3
• Q173PX is set on the system setting display of SW6RN-GSV
P.
• Tracking signal is input.