2 - 51
2 SYSTEM CONFIGURATION
2.4.5 Q172EX Serial absolute synchronous encoder interface module
Q172EX receive external signals required for serial absolute synchronous encoder.
(1) Q172EX/Q172EX-S1/Q172EX-S2/Q172EX-S3 name of parts
2
1
TREN
SY.ENC
SY.ENC2
SY.ENC1
Q172EX
2)
4)
1)
3)
2
1
Q172EX
5)
6)
MITSUBISHI
LITHIUM BATTERY
8)
7)
9)
(Note): The installation position of Q172EX-S2/Q172EX_S3 is only CPU base unit.
No.
Name Application
1) Module fixing hook
Hook used to fix the module to the base unit.
(Quick release installation)
Display the input status from the external equipment.
LED Details
SY.ENC
1, 2
Indicates to display the signal input status of
each serial absolute synchronous encoder.
(When the serial absolute synchronous encoder
cable connected property, LED is turned on.)
TREN
1, 2
Indicates to display the signal status of tracking
enable.
2) Mode judging LED
3) SY. ENC connector Input connector of the serial absolute synchronous encoder.
4) Module loading lever Used to install the module to the base unit.
5)
Module fixing screw
hole
Hole for the screw used to fix to the base unit
(M3×12 screw : Purchase from the other supplier)
6) Module fixing hook Hook used to fix to the base unit.
7) Battery connector For connection of battery lead wire.
8) Battery holder Used to the Install the Battery (A6BAT/MR-BAT) to the holder.
9)
Battery
(A6BAT/MR-BAT)
For Serial absolute synchronous encoder battery backup.