Mitsubishi Electronics Q172CPU9(N) Home Security System User Manual


 
5 - 5
5 TRIAL OPERATION AND ADJUSTMENT
Check servo amplifier
Check that the installed servo amplifiers
operate correctly.
CAUTION
Motion CPU
3)
4)
[Test mode
servo start-up
(Initial check) ]
[Test mode
servo start-up
(Model name check) ]
Read and displays the servo amplifier and
servomotor model names from the servo
amplifier after they have been transferred to
the servo amplifier during initial
communications with it.
Check servo amplifier communication
[Test mode
servo start-up
(Motor rotation
direction check) ]
Check servomotor rotation directions
Check that motor rotation directions are
correct for increased addresses and forward
JOG operation.
[Test mode
servo start-up
(Upper/lower stroke
limit check) ]
Check upper/lower stroke limits
Check that the upper/lower stroke limits
operate correctly.
[Test mode
servo start-up
(Motor speed check) ]
Check motor speed
Check that motor does not exceed rated
speed at maximum commanded. number of
revolution.
[Test mode
JOG operation ]
Check machine operation
Compare the set servomotor and servo amplifier
model names with the displayed model names.
Release brake on motor with brake.
If an error occurs, reset the emergency stop
and forced stop in a status where the emergency
stop and forced stop can be applied.
The system must have a mechanical allowance so
that the machine itself can stop even if the stroke
limits switch is passed through at the max. speed.
Axis No. and error description of servo amplifier which
detected errors are displayed on initial check screen.
Check the followings by making the machine
operate with the JOG operation of peripheral
device.
(1) Machine operates correctly
(no vibration, hunting, etc. )
(2) Stroke limits operate correctly
(3) Machine stops by the emergency
stop or forced stop.