2 - 24
2 SYSTEM CONFIGURATION
2.3 General Specifications
General specifications of Q173CPU(N)/Q172CPU(N) module are shown below.
Item Specification
Operating ambient
temperature
0 to 55°C
(32 to 131°F)
Storage ambient
temperature
-25 to 75°C
(Note-3)
(-13 to 167°F)
Operating ambient
humidity
5 to 95% RH
,
non-condensing
Storage ambient
humidity
5 to 95% RH
,
non-condensing
Frequency Acceleration Amplitude Sweep count
10 to 57Hz ——
0.075mm
(0.003inch)
Under
intermittent
vibration
57 to 150Hz 9.8m/s
2
——
10 to 57Hz ——
0.035mm
(0.001inch)
Vibration resistance Conforming
JIS B 3501,
IEC 61131-2
Under
continuous
vibration
57 to 150Hz 4.9m/s
2
——
10 times each
in X, Y, Z
directions
(For 80 min.)
Shock resistance Conforming to JIS B 3501, IEC 61131-2(147m/s
2
, 3 times in each of 3 directions X, Y, Z)
Operating ambience No corrosive gases
Operating altitude 2000m(6561.68ft.) or less
Installation location Inside control panel
Overvoltage category
(Note-1)
II or less
Pollution level
(Note-2
)
2 or less
(Note-1) : This indicates the section of the power supply to which the equipment is assumed to be connected between the
public electrical power distribution network and the machinery within premises.
Category II applies to equipment for which electrical power is supplied from fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300V is 2500V.
(Note-2) : This index indicates the degree to which conductive material is generated in terms of the environment in which
the equipment is used.
Pollution level 2 is when only non-conductive pollution occurs. A temporary conductivity caused by condensing
must be expected occasionally.
(Note-3) : Do not use or store the Motion CPU module under pressure higher than the atmospheric pressure of altitude 0m.
Doing so can cause an operation failure. When using the PLC under pressure, please contact your sales