Mitsubishi Electronics Q172CPU9(N) Home Security System User Manual


 
2 - 61
2 SYSTEM CONFIGURATION
2.4.6 Q173PX Manual pulse generator interface module
Q173PX receive external signals required for Manual pulse generator and Incremental
synchronous encoder (Voltage-output/Open collector type/Differential-output type).
(1) Q173PX/Q173PX-S1 name of parts
TREN
Q173PX
PULSER
Q173PX-S1
PLS.A
3
2
1
2)
4)
1)
3)
3
PLS.B
2
1
3
2
1
5)
7)
123456
KSD06S
ON
6)
No.
Name Application
1) Module fixing hook
Hook used to fix the module to the base unit.
(Quick release installation)
Display the input status from the external equipment.
LED Details
PLS.A 1 to 3
PLS.B 1 to 3
Input signal status of the Manual pulse
generator/Incremental synchronous
encoder phases A and B
TREN 1 to 3 Tracking enable signal
2) Mode judging LED
This LED is not turned on if it is not set the Q173PX in
the system settings.
3) PULSER connector
Input connector of the Manual pulse generator/Incremental
synchronous encoder.
4) Module loading lever Used to load the module to the base unit.
5)
Module fixing screw
hole
Hole for the screw used to fix to the base unit
(M3×12 screw : Purchase from the other supplier)