69
Operational Overview
Figure 70: Example 3 – Index5 is chained to Index6 using the Wait for Run Next Index input function.
How Alternate Mode Works
In addition to Jog, Index, and Home functions, the EP-I drive provides three basic modes of operation in Alternate Mode:
Analog Velocity, Analog Torque, and Pulse Mode.
When in Alternate Mode the drive will ignore all Index, Home, or Jog initiate requests. If the drive is indexing, homing, or
jogging when alternate mode is turned on, the drive will initiate a stop command and use the stop decel to ramp down to zero,
then it will switch into alternate mode.
Figure 71: Alternate Mode Screen - Pulse Mode
End of Index
Motion
End of Index
End of Index
Count
Index5
Index6
Dwell
Index6
Run Next
Index
Run Next Index
Input Function
Turned On
Index5