29
Setting Up Parameters
Figure 21: Jog View
Jog Velocity
This parameter specifies the velocity used for jogging with the Jog + or Jog - input functions.
Jog Fast Velocity
This parameter specifies the velocity used for fast jogging with the Jog Fast input function in conjunction with either the Jog
+ or Jog - input functions.
Acceleration
This parameter specifies the acceleration value to be used during the jog. The acceleration units are defined by the Time Scale
parameter on the User Units view.
Deceleration
This parameter specifies the deceleration value to be used during the jog. The deceleration units are defined by the Time Scale
parameter on the User Units view.
Max Motor Speed
This parameter specifies the maximum motor speed for the motor type selected on the Setup view.