Emerson Process Management 3420 Carbon Monoxide Alarm User Manual


 
Meter setup and configuration worksheet Reference, Installation, and Operations Manual
June 2013 3-9000-743 Rev S
327 Meter to Flow Computer Communication Worksheet
Freq 2 Direction Group 2
FO2A, FO2B
Forward:
FO2A AND FO2B output pulses
only when flow is in the forward
direction.
Reverse:
FO2A AND FO2B output
pulses only when flow is in
the reverse direction.
Absolute:
FO2A AND
FO2B output
pulses regard-
less of flow
direction.
Note: Both
outputs report
flow regardless
of the flow
direction.
Suggest config-
uring one of the
associated
digital outputs
to indicate
direction or use
phase relation-
ship.
Bidirectional:*
FO2A pulses
only when flow
is in the
forward direc-
tion.
FO2B pulses
only when flow
is in the
reverse direc-
tion.
The phase rela-
tionship setting
is ignored.
Freq B (FO2B
Phase Relationship
FO2B lags FO2A by 90
O
if
forward flow, or leads if reverse
flow.
FO2B leads FO2A by 90
O
if
forward flow, or lags if
reverse flow.
Max Freq 1000 Hz (overrange to 1500Hz
max).
5000 Hz (overrange to
7500Hz max).
Full Scale Flow Rate Refer to note in Modbus volume and flow rate units section of this table
Table E-2 Meter to Flow Computer Communication Worksheet (Sheet 6 of 9)