Emerson Process Management 3420 Carbon Monoxide Alarm User Manual


 
Reference, Installation, and Operations Manual Section 3: Installation
3-9000-743 Rev S June 2013
Frequency and Digital Output switch settings 79
3.5.2 Frequency and Digital Output switch settings
The meter provides two pairs of configurable frequency outputs (FO1A, FO1B, FO2A, and FO2B)
and four configurable digital outputs (DO1A, DO1B, DO2A, and DO2B). These outputs are
divided into two groups as follows:
Group 1: FO1A, FO1B, DO1A, DO1B
Group 2: FO2A, FO2B, DO2A, DO2B
The frequency and digital outputs are individually configured for “internally powered” mode or
“open collector” mode via CPU Board switch banks S8 and S9 (see Figure 3-25 and Figure 3-26).
See Section 2.4.4 for information on these modes.
Figure 3-25 CPU Board Frequency and Digital Output configuration switch banks
S 8
S 9
Group 2
Outputs
Group 1
Outputs
S8
S9