Emerson Process Management 3420 Carbon Monoxide Alarm User Manual


 
Meter setup and configuration worksheet Reference, Installation, and Operations Manual
June 2013 3-9000-743 Rev S
325 Meter to Flow Computer Communication Worksheet
Freq 1 Direction
Group 1
FO1A, FO1B
Forward:
FO1A and FO1B output pulses
only when flow is in the forward
direction.
Reverse:
FO1A and FO1B output
pulses only when flow is in
the reverse direction.
Absolute:
FO1A and FO1B
output pulses
regardless of flow
direction. Note:
Both outputs
report flow
regardless of the
flow direction.
Suggest config-
uring one of the
associated digital
outputs to
indicate direction
or use phase rela-
tionship.
Bidirectional:
FO1A pulses only
when flow is in the
forward direction.
FO1B pulses only
when flow is in the
reverse direction.
The phase rela-
tionship setting is
ignored.
Freq B (FO1B
Phase Relationship
FO1B lags FO1A by 90
O
if
forward flow, or leads if reverse
flow.
FO1B leads FO1A by 90
O
if
forward flow, or lags if
reverse flow.
Max Freq 1000 Hz (overrange to 1500Hz
max).
5000 Hz (overrange to
7500Hz max).
Full Scale Flow Rate Refer to note in Modbus volume and flow rate units section of this table
Digital Output Group 1 DO1A User Selection (Circle one) Results (Enter here)
Electrical Configuration TTL
“Internally Powered”
OC
“Open Collector”
Content Flow Direction Flow Validity
Polarity Normal Inverted*
*Note: Inverted operation - use if the output of the meter is reversed from what a flow computer is expecting. Selecting the check box inverts the digital output. This means that if
the output normally outputs a HIGH for a TRUE condition, selecting this check box changes the output to output a LOW for a TRUE condition.
Table E-2 Meter to Flow Computer Communication Worksheet (Sheet 4 of 9)
Description