156 AGA 8 Setup page
Section 5: Startup and meter configuration Reference, Installation, and Operations Manual
June 2013 3-9000-743 Rev S
1. From the Field Setup Wizard - AGA 8 Page, choose the desired settings:
AGA8 calculations to be performed:
Internally (by meter)
Base temperature
Base pressure
Base absolute pressure
Externally
Fixed
Live
Table 5-20 Field Setup Wizard - AGA 8 Setup
AGA8 method Configuration Parameters
Gross Method 1 Specific gravity: Relative density; used as input to the AGA8 Gross Methods 1 and 2 calculations
Reference temperature - for the specific gravity
Reference pressure - for specific gravity
CO2 - Mole percentage CO2 in the natural gas mixture
Hydrogen - Mole percentage of hydrogen
CO - Mole percentage of carbon monoxide
Volumetric gross heating
Molar density ref temperature: Reference temperature for the molar density; used as
input to the AGA8 Gross Method 1 calculation
Molar density ref pressure: Reference pressure for the molar density; used as input to the
AGA8 Gross Method 1 calculation
Gross Method 2 Specific gravity: Relative density; used as input to the AGA8 Gross Methods 1 and 2 calculations
Reference temperature - for the specific gravity
Reference pressure - for the specific gravity
CO2 - Mole percentage CO2 in the natural gas mixture
Hydrogen - Mole percentage of hydrogen
CO - Mole percentage of carbon monoxide
Nitrogen - Mole percentage of nitrogen in the natural gas mixture (AGA8 Gross Method 2
calculation)
AGA8 method Configuration Parameters
Detail Enter the amount of each of the 21 gas components as a percentage.
This option is only available in Mark III meters
Gas composition - Select either the Fixed or Live GC.
Fixed: Select this option to use the fixed gas composition stored in the meter for all
calculations for which they are required.
Live GC: Select this option to use a gas composition collected by the meter from a
gas chromatograph for all calculations for which they are required. This option is
only available for Mark III meters with a valid GCKey
Externally
Select if AGA8 calculations are done externally. The calculated values must then be
written to the meter using Daniel MeterLink or a flow computer. The following properties
must be entered. If a flow computer or SCADA system is used to write these values to the
meter, they do not have to be entered at this time.
Flow mass density
Flow compressibility
Base compressibility
Note: Mark II meters - Externally calculating the AGA8 calculations is only available for DFI boards running version 3.40 or later
firmware.