Reference, Installation, and Operations Manual Section 5: Startup and meter configuration
3-9000-743 Rev S June 2013
Ethernet initial connection steps 107
11. After a connection to the meter is established, use the
Meter|Communications Settings menu path to access the Communication Settings
window. Use the drop down menu to select options for baud rate or to enable or disable
RTS/CTS flow control.
When you finish the communications settings, click the button to apply
the settings.
Figure 5-4 Communications settings Ethernet port
12. Disconnect the standard Ethernet patch cable from the meter (if desired) and disable
the Mark III DHCP server by setting the meter CPU Board switch S2-2 to the OPEN
position (up away from the board).
13. In Daniel MeterLink, edit the meter directory record established above so that the
Ethernet connection uses the user-specified Ethernet settings. If desired, set the
Direct
and/or
Modem connection settings to the user-specified values.
At this point, the Mark III meter will only communicate at the user-configured IP address
and will not reply at the DHCP default address of 192.168.135.100.