Candle GC32-9172-00 Indoor Furnishings User Manual


 
KOGCM001KONCT303 493
KOGVT38E FETCH ATTEMPTED BEYOND END OF DATA REQUEST LRN=lrn
Explanation: An attempt to fetch rows beyond the last row of a query was
made. Normally, an end-of-table status value is returned when the last row of a
result table is fetched. This error message is issued when the VU Client issues a
VUFETCH service call after the end-of-table indication in a previous VUFETCH
call. The lrn value is the logical resource number associated with the VU request
handle.
System Action: VU Server completes the requested VUFETCH service call
and returns an error status to the VU Client.
User Response: Ensure the proper sequence of VU API service calls and that
VU API request handles are reused properly.
KOGVT40I colname(type,length)=value
Explanation: This message logs the retrieval of a column value in a row fetched
by a VUFETCH service call. The colname value indicates the column or relative
position of the column in the row to be fetched. The type value indicates the
format of the column (INTEGER, CHAR, BITSTRING, and so forth). The length
value indicates the length of the column value. The value displays the column
value retrieved.
System Action: VU Server proceeds to the next column in the row(s) to be
fetched.
User Response: None. This is a diagnostic message issued when TRACE
options have been enabled.
KOGVT99I VU THREAD IS TERMINATING
Explanation: This message is issued whenever a VU API service request has
completed execution. It can be used to mark the date and time at which the
service request completes execution.
System Action: VU API service request completes.
User Response: None. This is a diagnostic message issued when TRACE
options have been enabled.
KONAF001 OMEGAMON II for VTAM SHUTDOWN INITIATED VTAM IS NOT ACTIVE
Explanation: OMEGAMON II for VTAM detected that VTAM was inactive and
initiated shutdown.
System Action: None.
User Response: Investigate the reason for the VTAM outage.
Message Type: Warning.
KONAF002 COLLECTOR ERROR DURING SAMPLING OR RECORDING INTERVAL
PROCESSING MODULE(error_module)
Explanation: A collector called during sample or recording interval processing
abended. Diagnostics data are written to the ONSNAP dump dataset and to the
program check or snap table in the product work area extension.
System Action: OMEGAMON II for VTAM continues to run if possible.
User Response: Gather the preceding 30 minutes of the RKLVLOG and any
dumps that were produced or taken, and contact Candle Support Services.
Message Type: Internal error.