Candle GC32-9172-00 Indoor Furnishings User Manual


 
KLVHS001KLVSC009 15
User Response: Using the RC and service name, determine the cause of the
error, correct it, and restart CT/Engine.
Message Type: ERROR.
KLVLI001 LOCK MANAGER INTEGRITY ERROR
Explanation: An internal error occurred while processing a lock.
System Action: CT/Engine terminates.
User Response: Contact Candle Customer Support.
Message Type: ALERT.
KLVLR001 MAIN STORAGE SHORTAGE DETECTED, QUIESCE IN EFFECT
Explanation: CT/Engine detected a main storage shortage. To recover from the
shortage, CT/Engine will not accept any logons.
System Action: Users cannot logon or start a session.
User Response: None. However, if these messages occur frequently on your
system, you should examine the memory allocation parameters that are in effect.
These are the RKLVIN keywords MINIMUM, MAXIMUM, and RESERVE.
Message Type: ALERT.
KLVLR002 MAIN STORAGE SHORTAGE RELIEVED, QUIESCE RELEASED
Explanation: CT/Engine detected main storage availability and released the
quiesce caused by main storage shortage.
System Action: CT/Engine will now allow users to logon or start a session.
User Response: None.
Message Type: INFO.
KLVLR003 LOGICAL RESOURCE INTEGRITY ERROR
Explanation: While accessing the logical resource table, an integrity error was
detected.
System Action: For problem determination, a dump is generated with a user
abend code.
User Response: Contact Candle Customer Support.
Message Type: REPLY.
KLVLR004 PURGE/CLEANUP EXIT ERROR DETECTED, DUMP REQUESTED
Explanation: The CT/Engine logical resource manager detected an error during
resource purge or cleanup processing and has bypassed a purge/cleanup exit to
avoid further problems.
System Action: A dump is produced because DEBUG(Y) is in effect. Some
resources and storage may be hung.
User Response: Contact Candle Customer Support.