Candle GC32-9172-00 Indoor Furnishings User Manual


 
KLVHS001KLVSC009 35
KLVOP005 APPLICATION NOT ACCEPTING COMMANDS [text]
Explanation: A command was issued and directed to a CT/Engine application
that does not have a common interface. The optional text may be added by
CT/Engine modules to further describe the error.
System Action: The command terminates.
User Response: Validate the application applid to determine if a command
interface is defined. Reissue the command specifying a valid application name.
Message Type: ERROR.
KLVOP006 COMMAND NOT FOUND [text]
Explanation: The command or CLIST issued could not be located. The optional
text may be added by CT/Engine modules to further describe the error.
System Action: The command fails.
User Response: Verify that:
1. The command issued is a valid CT/Engine command, or
2. The CLIST is located in the CT/Engine command library (RKANCMD).
Message Type: ERROR.
KLVOP007 COMMAND NOT AUTHORIZED [text]
Explanation: A CT/Engine command issued by an unauthorized operator. The
optional text may be added by CT/Engine modules to further describe the error.
System Action: The command fails.
User Response: None.
Message Type: ERROR.
KLVOP008 clist CLIST COMPLETED
Explanation: The RKANCMD clist member clist has completed execution.
System Action: None.
User Response: None.
Message Type: REPLY
KLVOP009 command COMMAND COMPLETED
Explanation: The command command has completed its output.
System Action: None.
User Response: None.
Message Type: REPLY
KLVOP011 INVALID CLASS NAME: class
Explanation: The DISPLAY command was issued with an invalid class class.
System Action: The command fails.
User Response: Re-enter the command with a valid class.
Message Type: ERROR.