Candle GC32-9172-00 Indoor Furnishings User Manual


 
KMQxx001EKOCJ0046 235
KMQCI107E INVALID MINOR COMMAND
Explanation: The minor verb on the KMQCMD command is invalid.
System Action: The command is not executed.
User Response: Correct the KMQCMD command and resubmit it. For
complete KMQCMD command descriptions, see the Candle Command Center
Users Guide for MQSeries.
KMQCI108E INVALID KEYWORD keyword
Explanation: The named keyword in the KMQCMD command is invalid.
System Action: The command is not executed.
User Response: Correct the KMQCMD command and resubmit it. For
complete KMQCMD command descriptions, see the Candle Command Center
Users Guide for MQSeries.
KMQCI109E INVALID VALUE value FOR KEYWORD keyword
Explanation: The indicated value associated with the named keyword on the
KMQCMD command is invalid.
System Action: The command is not executed.
User Response: Correct the KMQCMD command and resubmit it. For
complete KMQCMD command descriptions, see the Candle Command Center
Users Guide for MQSeries.
KMQCI110E COMMAND NOT SUPPORTED
Explanation: CCC for MQSeries does not support the KMQCMD command
entered.
System Action: The command is not executed.
User Response: Correct the KMQCMD command and resubmit it. For
complete KMQCMD command descriptions, see the Candle Command Center
Users Guide for MQSeries.
KMQCI111E COMMAND PROCESSING ERROR - FUNCTION func RESPONSE = rs
REASON = rc
Explanation: An error occurred in the processing of the KMQCMD operator
command.
System Action: The command is not executed.
User Response: Search the TLVLOG for prior errors indicating the nature of
the problem. If the problem persists, contact Candle Customer Support.
KMQCI112E STARTUP ALREADY IN PROCESS
Explanation: A KMQCMD PERFORM STARTUP command was entered, but
CCC for MQSeries has already been started.
System Action: The command is not executed.
User Response: None. This is an informational message only.
KMQCI113W STARTUP ALREADY COMPLETED
Explanation: A KMQCMD PERFORM STARTUP was entered, but CCC for
MQSeries startup has already completed.
System Action: The command is not executed.
User Response: None. This is an informational message only.