278 Candle Products Messages Manual (KLVHSKONCT)
KMQMQ210E MQI RECORD TYPE IS INVALID, QMGR=queue_manager_name, hex
Explanation: The MQI data processor detected that the incoming MQI record is
of an invalid type. queue_manager_name is the name of monitored queue
manager, hex is the hexadecimal display of the key portion of the MQI record.
System Action: The MQI record is not processed.
User Response: Contact Candle Customer Support.
KMQMQ211E MQI TRACING IS DISABLED FOR QMGR=queue_manager_name, module
RC=rc, REASON=reason
Explanation: An error was detected for the specified queue manager during
MQI tracing initialization. module is the name of module which detected the error,
rc is the return code and reason is the reason code.
System Action: MQI tracing is disabled.
User Response: Check the RKPDLOG for Persistent Data Store error messages
and make sure that at least one of the datasets in the RKMQDSA group is
available for write access.
KMQMQ212W MQI HANDLE TRANSLATION FAILED. QMGR=qmgr,
APPLICATION=application id, TRAN/PGM=tran/pgm name. THIS MAY
RESULT IN INCOMPLETE APPLICATION QUEUE STATISTICS.
Explanation: The identified application and transaction/program was in
progress at the time that OMEGAMON XE for WebSphere MQ Monitoring started
monitoring. An attempt to perform handle translation to determine the name of
the queue being accessed failed. This may occur if the identified application
thread terminates immediately after the MQI call.
System Action: Processing continues. Queue-related statistics are not
updated.
User Response: None.
KMQMQ213E KMQAPI REQUESTED API module NOT SUPPORTED.
Explanation: The KMQAPI router module has encountered a request for an API
that is not supported.
System Action: The request fails.
User Response: Record information and contact Candle Customer Support.
KMQMQ214E KMQAPI ERROR; API=module, RESPONSE=r1, REASON=r2
Explanation: The KMQAPI router module detected an error from the specified
API module.
System Action: The data requested is unavailable.
User Response: If the problem persists, contact Candle Customer Support
Note, it is possible for this message to occur at shutdown without causing serious
problems.
KMQMQ215E APPLICATION DATA SAMPLE PROCESSOR TERMINATED.
QMGR=queue_manager_name, RC=rc
Explanation: The application data sample processor unexpectedly terminated.
queue_manager_name is the name of monitored queue manager, rc is the reason
code.
System Action: The application data sample processor terminates.