Emerson Process Management Rosemount 2410 Water Heater User Manual


 
Reference Manual
300530EN, Rev BA
September 2012
Rosemount 2410 Series
4-2
Section 4. Configuration
4.2 INTRODUCTION A Raptor system includes a wide range of devices for tank monitoring. It is a
flexible and scalable system which can be adapted to various applications
and small or large tank farms. A typical Raptor system includes one or more
of the following devices:
control room PC with Rosemount TankMaster program for operational
control
Field Communication Unit (FCU) that collects measurement data from
Rosemount 2410 Tank Hubs
Rosemount 2410 Tank Hub which collects measurement data from field
devices on the tanks
various field instruments such as the Rosemount 5900S Radar Level
Gauge, Rosemount 2240S Multi-input Temperature Transmitter,
Rosemount 2230 Graphical Field Display, Rosemount 3051S Pressure
Transmitter
Smart Wireless Gateway and Smart Wireless THUM Adapter for
wireless communication between field devices and control room host
system
See the Raptor Technical Description (Document no. 704010EN) for a
comprehensive description of the Raptor system components.
4.3 CONFIGURATION
TOOLS
The Rosemount 2410 Tank Hub is configured by using the Rosemount
TankMaster Winsetup configuration program. Winsetup is a user-friendly
software package that includes basic configuration options as well as
advanced configuration and service functions.
See the Raptor System Configuration Manual (Document no. 300510EN) for
more information on using the TankMaster WinSetup software to configure
the Rosemount 2410 Tank Hub.
See also the Raptor Wireless TankGauging System reference manual
(Document no. 300570EN) for information on how to set up a Rosemount
2410 in a WirelessHART system.