Emerson Process Management Rosemount 2410 Water Heater User Manual


 
Reference Manual
300530EN, Rev BA
September 2012
6-27
Rosemount 2410
Section 6. Service and Troubleshooting
Other Memory Error Input register no. 6108:
Bit 0: CheckSum
Bit 1: Stack
Contact Emerson Process
Management/Rosemount TankGauging
service department
Sys Error Input register no. 6110.
Bit 0: Task Supervisor
Display Error Input register no. 6112.
Bit 0: Hardware
Bit 1: Com
Bit 2: Configuration
Aux Error Input register no. 6114.
Bit 0: Internal temperature out of limits
Bit 1: Internal temp measurement failed
Bit 2: Internal temperature device failed
Bit 3: Relay 1
Bit 4: Relay 2
Bit 5: Power
FF Stack Error Input register no. 6116.
Tankbus Communication Error Input register no. 6118.
Bit 0: Unknown device connected to the
Tankbus
Host Communication Error Input register no. 6120.
Bit 1: Hardware Primary modem
Bit 2: Hardware Secondary modem
Bit 3: Illegal Primary modem
Bit 4: Illegal Secondary modem
Contact Emerson Process
Management/Rosemount TankGauging
service department
Data Manager Error Input register no. 6122.
Bit 1: Tank configuration
Configuration Error Input register no. 6124.
Message Description Action