Emerson Process Management Rosemount 2410 Water Heater User Manual


 
Reference Manual
300530EN, Rev BA
September 2012
Rosemount 2410
C-4
Appendix C. Advanced Configuration
C.3 PRIMARY BUS The Rosemount 2410 has a Primary Bus which is used for communication
with a Rosemount 2160 Field Communication Unit (FCU) or a control room
computer. The Primary Bus supports TRL2 and RS-485 bus communication.
To open the Primary Bus window:
1. In the WinSetup workspace click the right mouse button on the 2410
icon.
2. Choose the Properties option.
3. In the 2410 Tank Hub window select the Configuration tab.
4. Click the Primary Bus button.
Figure C-2. Primary Bus
Configuration window
The Primary Bus Configuration window allows you to configure protocol,
baudrate, and other communication settings. This may, for example, be useful
for maximizing communication speed when upgrading the software of a 2410
Tank Hub.
To change communication parameters:
1. In the Configuration field, change from Standard to Non Standard.
2. Choose the desired communication parameter values.
3. Click OK to store the current configuration and close the Primary Bus
Configuration window.