Emerson Process Management Rosemount 2410 Water Heater User Manual


 
Reference Manual
300530EN, Rev BA
September 2012
3-7
Rosemount 2410
Section 3. Installation
3.4.6 Power Budget The Rosemount 2410 Tank Hub delivers 250 mA to the Tankbus. In Smart
Wireless systems a 2410 Tank Hub equipped with active analog
inputs/outputs may deliver 200 mA. The number of tanks served by the 2410
depends on the type of connected field devices and their power
consumption
(1)
. Power consumption per field device is listed in Table 3-2
below:
Table 3-2. Power consumption
for various Raptor devices
The Rosemount 2410 Tank Hub is available in a single tank version as well as
a multiple tank version which supports up to 10 tanks
(2)
.
(1) May be fewer than the 16 devices per segment, stated in the FOUNDATION™ fieldbus stan-
dard.
Field device Power consumption
5900S Radar Level Gauge
50 mA
5900S Radar Level Gauge,
2-in-1 solution
100 mA
5300 or 5400 Series Radar Level
Gauge
21 mA
Rosemount 2230 Graphical Field
Display
30 mA
Rosemount 2240S Multi-input
Temperature Transmitter
30 mA including MST and WLS
Rosemount 644 Temperature
Transmitter
11 mA
Rosemount 3051S and Rosemount
2051 Pressure Transmitters
18 mA
(2) Maximum five Rosemount 5300 or 5400 level transmitters.