26
COMP A2
GRN/YEL
TRAN1
H2
H3
H4
SECONDARY 24V
RED
FC2
BLK-1
BLK-2
BLK-3
FU3
SW2
C1
A1
B1
1
2
3
H1
X1
CONNECT FOR
APPROPRIATE
PRIMARY VOLTAGE
SEE TABLE 1
1
2
3
CB1A
11
12
13
TO FUSED
DISCONNECT
PER NEC
OPTIONAL
DISCONNECT
3.2 AMPS
CB3
1
2
3
T3
T1
T2
T3
T1
T2
3
2
1
LOW AMBIENT OPERATION (MOTORMASTER V) FIOP/ACCESSORY
GRN/YEL
GRN/YEL
XF
VIO
11 21
12
22
13 23
11 21
12 22
13 23
CA1
BLK
YEL
BLU
11 21
12 22
13 23
CA2
11
12
13
21
22
23
CCB-1
BLK
YEL
BLU
BLK
YEL
BLU
YEL
BLU BLK
YEL
BLU
BLK
11
12
13
21
22
23
CCB-2
BLK
YEL
BLK
380V,460V,575V
ONLY
BLU
YEL
BLU
GRN/YEL
OFM1
FC3
1
2
3
11 21
12
22
13 23
COMP B2
1
2
3
T3
T1
T2
T3
T1
T2
3
2
1
GRN/YEL
GRN/YEL
11 21
12 22
13 23
CB1
BLK
YEL
BLU
11 21
12 22
13 23
CB2
11
12
13
21
22
23
CCB-3
BLK
YEL
BLU
BLK
YEL
BLU
YEL
BLU BLK
YEL
BLU
BLK
11
12
13
21
22
23
CCB-4
BLK
YEL
380V,460V,575V
ONLY
208/230V ONLY
BLU
BLU
BLU
BLU
BLU
YEL
YEL
YEL
YEL
BLK
BLK
BLK
BLK
BLK-1
BLK-2
BLK-3
BLK
YEL
BLU
BLK
YEL
BLU
YEL
BLUBLK
BRN
FU1
BLK
FU2
YEL
GRN/YEL
TRAN2
COM
RED
7
TB4
VIO
6
TB4
VIO
C
TB1
BLK
YEL
BRN
BRN
PRIMARY
PRIMARY
CONNECT FOR
APPROPRIATE
PRIMARY VOLTAGE
SEE TABLE 2
X2
* MM SIGNAL CONNECTION
VOLTAGE
TB HZ
208/230/460/575
160
380
13A 60
FCB2/FB2
NOTES:
1. FACTORY WIRING IS IN ACCORDANCE WITH UL 1995 STANDARDS.
ANY FIELD MODIFICATIONS OR ADDITIONS MUST BE IN
COMPLIANCE WITH ALL APPLICABLE CODES.
2. USE 75
C MIN WIRE FOR FIELD POWER SUPPLY.
3. ALL FIELD INTERLOCK CONTACTS MUST HAVE A MIN RATING OF
2 AMPS @ 24VAC SEALED. SEE FIELD INTERLOCK WIRING.
4. COMPRESSOR AND FAN MOTORS ARE THERMALLY PROTECTED--
THREE PHASE MOTORS PROTECTED AGAINST PRIMARY SINGLE
PHASE CONDITIONS.
5. TERMINALS 13 & 14 OF LVT ARE FOR FIELD CONNECTION
OF REMOTE ON-OFF. THE CONTACT MUST BE RATED FOR DRY
CIRCUIT APPLICATION CAPABLE OF HANDLING A 5VDC
1 MA TO 20 MA LOAD.
6. FOR 500 SERIES UNIT OPERATION AT 208-3-60V LINE VOLTAGE,
TRAN1 PRIMARY CONNECTIONS MUST BE MOVED TO TERMINALS H3 & H4.
10. MP-A1 NOT USED IN THE FOLLOWING UNITS:
035-045: ALL UNITS
11. MP-A2 NOT USED IN THE FOLLOWING UNITS:
035-045: ALL UNITS
12. MP-B1 NOT USED IN THE FOLLOWING UNITS:
035,040: ALL UNITS
045-060: 460V UNITS
13. MP-B2 NOT USED IN THE FOLLOWING UNITS:
035,040: ALL UNITS
045-060: 460V UNITS
14. JUMPER PLUG REQUIRED WHEN MP NOT USED
7. FOR 575-3-60V UNITS, FAN CIRCUIT BREAKER FCB2
IS REPLACED WITH FUSE BLOCK FB2.
SEE NOTE 7
BLK
BLU
YEL
VOLTAGE SERIES
TERMINAL
CONNECTIONS
FOR PRIMARY SIDE
575-3-60 100 H1 & H2
380-3-60 200 H1 & H2
230-3-60 500 H2 & H4
208-3-60 500 H3 & H4
460-3-60 600 H1 & H4
TABLE 1
UNIT VOLTAGE
REPLACE
WITH
FNQ-R-3.5
FU1 & FU2
FUSE
NUMBER
380-3-60
TRAN
SIZE
200VA
FNQ-R-2.5
208/230-3-60
FNM-10
FU3 (24V)
380-3-60,460-3-60,575-3-60
200VA
208/230-3-60
VOLTAGE SERIES
TERMINAL
CONNECTIONS
FOR PRIMARY SIDE
575-3-60 100 COM & 575
380-3-60 200
230-3-60 500
208-3-60 500
460-3-60 600
TABLE 2
460-3-60
575-3-60
FNQ-R-2
FNQ-R-1.5
COM & 380
COM & 230
COM & 208
COM & 460
208
230
380
400
575
460
8. FOR UNITS WITH LOW AMBIENT MOTOR MASTER V FIOP/ACCESSORY,
030-050: FAN CONTACTOR FC1 IS REPLACED WITH MOTORMASTER RELAY MMR.
SECONDARY 24V
3.2 AMPS
CB4
RED
3
3
2
2
1
1
J2
BRN
RED
2
2
1
J1
1
3
3
EXV
BRN
RED
CWFS
CH-A2
BLU
BLK
CH-B1
BLU
BLK
CH-A1
BLU
BLK
CH-B2
BLU
BLK
GRN/YEL
OFM2
1
2
3
BLK-1
BLK-2
BLK-3
GRN/YEL
FC1
1
2
3
11 21
12
22
13 23
BLK-1
BLK-2
BLK-3
BLU
YEL
BLK
CWP1
CWP2
MS-CWP2
MS-CWP1
BLK
BLK
BLK
BLK
BLK
BLK
L3
L1
L2
CWP1
WATER
PUMP
L3
L1
L2
CWP2
WATER
PUMP
L1 T1
L2
T2
L3
T3
L1
L2
L3
T1
T2
T3
L1 T1
L2
T2
L3
T3
L1
L2
L3
T1
T2
T3
BLK
YEL
BLU
BLK
YEL
BLU
GRN/YEL
GRN/YEL
VOLTAGE SERIES
TERMINAL
CONNECTIONS
FOR PRIMARY SIDE
TERMINAL
CONNECTIONS FOR
SECONDARY SIDE
575-3-60 100 H1-H2 XF-X2
230-3-60 400,500 H2-H4 XF-X2
208-3-60 500 H3-H4 XF-X2
460-3-60 600 H1-H4 XF-X2
TRAN3
SECONDARY
115V
WHT
RESET
TEST
GRN-YEL
GFI-CO
FIOP/ACCESSORY
BRASS SCREW
SILVER SCREW
WHT
FU4
X3
X1
LOAD
LINE
BRASS SCREW
SILVER SCREW
BLK
2
2
XF
H4
H1
HF
H2
H3
BLK
1
FU6
RED
1
FU5
~
~
~
FU5 & FU6
500VA
FNM-6
FU4 (115V)
380-3-60,460-3-60,575-3-60
500VA
208/230-3-60
460-3-60,575-3-60
208/230-3-60,230-3-60
FNQ-R-2.5
FNQ-R-3.5
9. IF CHILLED WATER PUMP INTERLOCK IS USED,
REMOVE JUMPER FROM TERMINAL 11 TO 17 AND
CHILLED WATER PUMP FIOP
WIRE INTERLOCK CONTACT ACROSS TERMINALS 11 & 17.
050-060: 460V UNITS WITHOUT DIGITAL SCROLL
050-060: 460V UNITS
GRN/YEL
OFM3
OFM4
(055,060 ONLY)
(055,060 ONLY)
GRN/YEL
1
2
3
BLK-1
BLK-2
BLK-3
OFM4 (055,060)
OFM3 (035-050)
L1 T1
L2 T2
L3 T3
MMR
11 14
*1
2
YEL
VIO
MM-A
GRN/YEL
FC2
BLK-1
BLK-2
BLK-3
1
2
3
11 21
12
22
13 23
GRN/YEL
OFM1
FC1
1
2
3
11 21
12
22
13 23
BLK-1
BLK-2
BLK-3
BLK
YEL
BLU
BLK
YEL
BLU
FCB2/FB2
SEE NOTE 7
GRN/YEL
OFM2
1
2
3
BLK-1
BLK-2
BLK-3
OFM3
(055,060 ONLY)
(055,060 ONLY)
GRN/YEL
BLK
YEL
055,060: FAN CONTACTOR FC3 IS REPLACED WITH MOTORMASTER RELAY MMR..
208/230V ONLY
BLK
YEL
BLU
11
12
13
21
22
23
BLK
YEL
BLU
11
12
13
21
22
23
FB1
BLK
YEL
BLU
FB3
BLK
YEL
BLU
11
12
13
21
22
23
11
12
13
21
22
23
BLK
YEL
BLU
HIGH SCCR
ONLY
FB1
BLK
YEL
BLU
FB3
BLK
YEL
BLU
11
12
13
21
22
23
11
12
13
21
22
23
BLK
YEL
BLU
HIGH SCCR
ONLY
BLK
25
2
RED
FROM
AUX-J4
YEL
BLUBLK
FB2 NONE
LP-CC-20575-3-60
LP-CC-20
380-3-60,460-3-60,575-3-60
NONE
208/230-3-60
KTK-R-15
380-3-60,460-3-60,575-3-60
NONE
KTK-R-20208/230-3-60
FB1
(NO MM)
FB1
(WITH MM)
LP-CC-20
380-3-60,460-3-60,575-3-60
NONE
208/230-3-60
FB3
3
3
2
2
1
1
J2
BRN
VIO
2
2
1
J1
1
3
3
MBB
BRN
RED
3
3
2
2
1
1
J2
2
J1
1
3
FIOP/ACCESSORY
EMM
BRN
RED
12
2
11
1
J1
DGS FIOP
AUX
2
1
3
2
1
UPC FIOP
UPC
GND
HOT
24VAC
BRN
VIO
42
86
BLK
YEL
COOLER/PUMP
HEATERS
(208/230,230V)
1
2
3
BLK
BLK
WHT
COOLER/PUMP
HEATERS
(380,460,575V)
3
2
BLK
BLK
~
~
~
~
WHT
~~
42
86
BLK
YEL
COOLER/PUMP
HEATERS
(208/230,230V)
1
2
3
BLK
BLK
WHT
COOLER/PUMP
HEATERS
(380,460,575V)
3
2
BLK
BLK
~
~
~
~
WHT
~~
VIO
BRN
BRN
BLU
31
240 1/4W
CHC
CHC
CHC
CHC
STANDARD
TERMINAL
BLOCK
PER NEC
TO FUSED DISCONNECT
21
22
23
TB1A
EQUIP GND
COMP A1
COMP B1
CSB-A1
CSB-A2
CSB-B1
CSB-B2
Fig. 7A — Typical Wiring Schematic, 30RAP035-060 Units — Power Wiring
a30-
5283