Carrier 30RAP010-060 Air Conditioner User Manual


 
24
COMP A2
TRAN1
H2
H3
H4
SECONDARY 24V
RED
FC2
FU3
SW2
C1
A1
B1
H1
X1
CONNECT FOR
APPROPRIATE
PRIMARY VOLTAGE
SEE TABLE 1
1
2
3
CB1A
11
12
13
TO FUSED
DISCONNECT
PER NEC
OPTIONAL
DISCONNECT
3.2 AMPS
CB3
1
2
3
T3
T1
T2
T3
T1
T2
3
2
1
LOW AMBIENT OPERATION (MOTORMASTER V) FIOP/ACCESSORY
GRN/YEL
GRN/YEL
XF
VIO
11 21
12
22
13 23
11 21
12 22
13 23
CA1
BLK
YEL
BLU
11 21
12 22
13 23
CA2
11
12
13
21
22
23
CCB-1
BLK
YEL
BLU
BLK
YEL
BLU
YEL
BLU BLK
YEL
BLU
BLK
11
12
13
21
22
23
CCB-2
BLK
YEL
BLK
380V,460V,575V
ONLY
BLU
YEL
BLU
GRN/YEL
OFM2
1
2
3
BLU
BLU
BLU
YEL
YEL
YEL
BLK
BLK
BLK
BLK-1
BLK-2
BLK-3
YEL
BLUBLK
FU1
BLK
FU2
YEL
GRN/YEL
RED
7
TB4
6
TB4
VIO
C
TB1
BRN
PRIMARY
X2
* MM SIGNAL CONNECTION
VOLTAGE
ZHBT
208/230/460/575
061
380
06A31
NOTES:
1. FACTORY WIRING IS IN ACCORDANCE WITH UL 1995 STANDARDS.
ANY FIELD MODIFICATIONS OR ADDITIONS MUST BE IN
COMPLIANCE WITH ALL APPLICABLE CODES.
C MIN WIRE FOR FIELD POWER SUPPLY.
3. ALL FIELD INTERLOCK CONTACTS MUST HAVE A MIN RATING OF
2 AMPS @ 24VAC SEALED. SEE FIELD INTERLOCK WIRING.
4. COMPRESSOR AND FAN MOTORS ARE THERMALLY PROTECTED--
THREE PHASE MOTORS PROTECTED AGAINST PRIMARY SINGLE
PHASE CONDITIONS.
5. TERMINALS 13 & 14 OF LVT ARE FOR FIELD CONNECTION
OF REMOTE ON-OFF. THE CONTACT MUST BE RATED FOR DRY
CIRCUIT APPLICATION CAPABLE OF HANDLING A 5VDC
1 MA TO 20 MA LOAD.
6. FOR 500 SERIES UNIT OPERATION AT 208-3-60V LINE VOLTAGE,
TRAN1 PRIMARY CONNECTIONS MUST BE MOVED TO TERMINALS H3 & H4.
9. MP-A1 NOT USED IN THE FOLLOWING UNITS:
018,020: ALL UNITS
10. MP-A2 NOT USED IN THE FOLLOWING UNITS:
018-020: ALL UNITS
11. JUMPER PLUG REQUIRED WHEN MP NOT USED
VOLTAGE SERIES
TERMINAL
CONNECTIONS
FOR PRIMARY SIDE
575-3-60 100 H1 & H2
380-3-60 200 H1 & H2
230-3-60 500 H2 & H4
208-3-60 500 H3 & H4
460-3-60 600 H1 & H4
TABLE 1
UNIT VOLTAGE
REPLACE
WITH
FNQ-R-3.5
FU1 & FU2
FUSE
NUMBER
380-3-60
TRAN
SIZE
200VA
FNQ-R-2.5
208/230-3-60
FNM-10
FU3 (24V)
380-3-60,460-3-60,575-3-60
200VA
208/230-3-60
460-3-60
575-3-60
FNQ-R-2
FNQ-R-1.5
7. FOR UNITS WITH LOW AMBIENT MOTOR MASTER V FIOP/ACCESSORY,
FAN CONTACTOR FC1 IS REPLACED WITH MOTORMASTER RELAY MMR.
CH-A2
BLU
BLK
CH-A1
BLU
BLK
GRN/YEL
FC1
1
2
3
11 21
12
22
13 23
BLK-1
BLK-2
BLK-3
CWP1
CWP2
MS-CWP2
MS-CWP1
BLK
BLK
BLK
BLK
BLK
BLK
L3
L1
L2
CWP1
WATER
PUMP
L3
L1
L2
CWP2
WATER
PUMP
L1 T1
L2
T2
L3
T3
L1
L2
L3
T1
T2
T3
L1 T1
L2
T2
L3
T3
L1
L2
L3
T1
T2
T3
BLK
YEL
BLU
BLK
YEL
BLU
GRN/YEL
GRN/YEL
VOLTAGE SERIES
TERMINAL
CONNECTIONS
FOR PRIMARY SIDE
TERMINAL
CONNECTIONS FOR
SECONDARY SIDE
575-3-60 100 H1-H2 XF-X2
230-3-60 400,500 H2-H4 XF-X2
208-3-60 500 H3-H4 XF-X2
460-3-60 600 H1-H4 XF-X2
TRAN3
SECONDARY
115V
WHT
RESET
TEST
GRN-YEL
GFI-CO
FIOP/ACCESSORY
BRASS SCREW
SILVER SCREW
WHT
FU4
X3
X1
LOAD
LINE
BRASS SCREW
SILVER SCREW
BLK
2
2
XF
H4
H1
HF
H2
H3
BLK
1
FU6
RED
1
FU5
~
~
~
AV0056UF & 5UF
FNM-6
FU4 (115V)
380-3-60,460-3-60,575-3-60
500VA
208/230-3-60
460-3-60,575-3-60
208/230-3-60,230-3-60
FNQ-R-2.5
FNQ-R-3.5
8. IF CHILLED WATER PUMP INTERLOCK IS USED,
REMOVE JUMPER FROM TERMINAL 11 TO 17 AND
CHILLED WATER PUMP FIOP
WIRE INTERLOCK CONTACT ACROSS TERMINALS 11 & 17.
025,030: 460V UNITS WITHOUT DIGITAL SCROLL
025,030: 460V UNITS
GRN/YEL
OFM1
GRN/YEL
1
2
3
BLK-1
BLK-2
BLK-3
L1 T1
L2 T2
L3 T3
MMR
11 14
*1
2
YEL
VIO
MM-A
FC2
11 21
12
22
13 23
GRN/YEL
OFM2
1
2
3
BLK-1
BLK-2
BLK-3
BLK
YEL
BLU
208/230V ONLY
BLK
YEL
BLU
BLK
25
2
RED
FROM
AUX-J4
LP-CC-20
380-3-60,460-3-60,575-3-60
NONE
208/230-3-60
KTK-R-15
380-3-60,460-3-60,575-3-60
NONE
KTK-R-20208/230-3-60
FB1
(NO MM)
FB1
(WITH MM)
LP-CC-20
380-3-60,460-3-60,575-3-60
NONE
208/230-3-60
FB2
OFM1
BLK
YEL
BLU
BLK
YEL
BLU
FB1
BLK
YEL
BLU
FB3
BLK
YEL
BLU
11
12
13
21
22
23
11
12
13
21
22
23
HIGH SCCR
ONLY
BLK
YEL
BLU
BLK
YEL
BLU
BLK
YEL
BLU
FB3
11
12
13
21
22
23
HIGH SCCR
ONLY
FB1
11
12
13
21
22
23
11
12
13
21
22
23
42
86
BLK
YEL
COOLER/PUMP
HEATERS
(208/230,230V)
1
2
3
BLK
BLK
WHT
COOLER/PUMP
HEATERS
(380,460,575V)
1
3
2
BLK
BLK
~
~
~
~
WHT
~~
FB2
YEL
BLUBLK
LP-CC-20
380-3-60,460-3-60,575-3-60
NONE
208/230-3-60
FB3
42
86
BLK
YEL
COOLER/PUMP
HEATERS
(208/230,230V)
1
2
3
BLK
BLK
WHT
COOLER/PUMP
HEATERS
(380,460,575V)
1
3
2
BLK
BLK
~
~
~
WHT
~~
5
TB4
C
TB1
RED BRN
BRN
VIO
BRN
3
3
2
2
1
1
J2
BRN
RED
2
2
1
J1
1
3
3
EXV
CWFS
3
3
2
2
1
1
J2
BRN
VIO
2
2
1
J1
1
3
3
MBB
BRN
RED
3
3
2
2
1
1
J2
2
J1
1
3
FIOP/ACCESSORY
EMM
BRN
RED
12
2
11
1
J1
DGS FIOP
AUX
2
1
3
2
1
UPC FIOP
UPC
GND
HOT
24VAC
BRN
VIO
240 1/4W
CHC
CHC
CHC
CHC
VIO
BRN
BRN
BLU
31
STANDARD
TERMINAL
BLOCK
PER NEC
TO FUSED DISCONNECT
21
22
23
TB1A
EQUIP GND
COMP A1
CSB-A1
CSB-A2
Fig. 6A — Typical Wiring Schematic, 30RAP018-030 Units — Power Wiring
a30-4965