Explanation of functions (parameters)
CAUTION
1. Set 60Hz in Pr. 3 "base frequency" when using a Mitsubishi constant-torque
motor.
2. When automatic torque boost is selected, Pr. 47 is invalid. When automatic
torque boost is selected, setting "- - -" or "888" in Pr. 19 uses the rated
output voltage.
REMARKS
* The RT signal serves as the second function selection signal and makes the other second
functions valid.
♦Related parameters♦
•
When rated motor frequency is "50Hz" ⇒ Pr. 14 "load pattern selection" (refer to page 83)
• RT signal (second function "Pr. 47") setting ⇒ Pr. 60 to Pr. 63 (input terminal function selection)
(refer to page 109)
• Motor setting ⇒ Pr. 71 "applied motor" (refer to page 80)
• Automatic torque boost selection ⇒ Pr. 98 "automatic torque boost selection (motor capacity)"
(refer to page 133)