Output terminal function
2
FUNCTIONS
2.4.2 Output frequency detection (Pr. 42 , Pr. 43 )
<Setting>
Refer to the above chart and set the corresponding parameters.
When Pr. 43 "output frequency detection for reverse rotation" "- - -", the Pr.42
setting applies to forward rotation and the Pr.43 setting applies to reverse rotation.
Use Pr. 64 or Pr. 65 (output terminal function selection) to assign the terminal used
for FU signal output.
, Refer to , (page 78).
Refer to (page 73).
Refer to (page 75).
The output frequency
detection signal (FU) is
output when the output
frequency reaches or
exceeds the setting. This
function can be used for
electromagnetic brake
operation, open signal, etc.
You can also set the
frequency detection used
exclusively for reverse
rotation.
This function is effective for switching the timing of electromagnetic brake
operation between forward rotation (rise) and reverse rotation (fall) during
vertical lift operation, etc.
Parameter Name
Factory
Setting
Setting
Range
Remarks
42
Output frequency
detection
6Hz 0 to 120Hz

Setting is
enabled when
Pr. 30 = "1".
43
Output frequency
detection for reverse
rotation
- - -
0 to 120Hz,
- - -
- - -: Same as
Pr. 42 setting
CAUTION
Using Pr. 64 or Pr. 65 to change the terminal assignment may affect the other
functions. Make setting after confirming the function of each terminal.
Related parameters
Assignment of FU signal to terminal Pr. 64 "RUN terminal function selection", Pr. 65 "A, B, C
terminal function selection" (refer to page 111)
Forward
rotation
Reverse
rotation
Time
Output
signal
FU
Output
frequency (Hz)
Pr.42
Pr.43
ON
ON
OFF OFF OFF