32
Up to ten Special I/O Units may be mounted in any slot of the CPU Rack or Ex-
pansion I/O Racks. Up to five Slave Racks may be used, whether one or two
Masters are used. IR area words are allocated to Special I/O Units and Slave
Racks by the unit number on the Unit, as shown in the following tables.
Special I/O Units Slave Racks
Unit number IR address Unit number IR address
0 100 to 109 0 050 to 059
1 110 to 119 1 060 to 069
2 120 to 129 2 070 to 079
3 130 to 139 3 080 to 089
4 140 to 149 4 090 to 099
5 150 to 159
6 160 to 169
7 170 to 179
8 180 to 189
9 190 to 199
The C500-RT001/002-(P)V1 Remote I/O Slave Rack may be used, but it re-
quires 20 I/O words, not 10, and therefore occupies the I/O words allocated to 2
C200H Slave Racks, both the words allocated to the unit number set on the rack
and the words allocated to the following unit number. When using a C200HS
CPU, do not set the unit number on a C500 Slave Rack to 4, because there is no
unit number 5. I/O words are allocated only to installed Units, from left to right,
and not to slots as in the C200HS system.
I/O words between IR 200 and IR 231 are allocated to Optical I/O Units and I/O
Terminals by unit number. The I/O word allocated to each Unit is IR 200+n,
where n is the unit number set on the Unit.
Remote Master I/O Units and Host Link Units do not use I/O words, and the PC
Link Units use the LR area, so words allocated to the slots in which these Units
are mounted are available as work words.
Bit Allocation for I/O Units An I/O Unit may require anywhere from 8 to 16 bits, depending on the model.
With most I/O Units, any bits not used for input or output are available as work
bits. Transistor Output Units C200H-OD213 and C200H-OD411, as well as Triac
Output Unit C200H-OA221, however, uses bit 08 for the Blown Fuse Flag. Tran-
sistor Output Unit C200H-OD214 uses bits 08 to 11 for the Alarm Flag. Bits 08 to
15 of any word allocated to these Units, therefore, cannot be used as work bits.
The Interrupt Input Unit uses the 8 bits of the first I/O word allocated to its slot in
the CPU Rack. (An Interrupt Input Unit will operate as a normal Input Unit when
installed in an Expansion I/O Rack.) The other 24 bits allocated to its slot in the
CPU Rack can be used as work bits.
Allocation for Special I/O
Units and Slave Racks
Allocation for Optical I/O
Units and I/O Terminals
Allocation for Remote I/O
Master and Link Units
Bit Allocation for Interrupt
Input Units
IR Area Section 3-3