Omron C200HS Garage Door Opener User Manual


 
419
Parameters Name, TC Number (Command)
In “Name”, specify the name of the instruction, in four characters, for changing
the SV. In “TC number”, specify the timer/counter number used for the instruc-
tion.
Instruction name
Classification TC number
OP1 OP2 OP3 OP4
range
T I M (S) TIMER
0000 to 0511
T I M H HIGH-SPEED TIMER
C N T (S) COUNTER
C N T R REVERSIBLE COUNTER
T T I M TOTALIZING TIMER
(S): Space
Operand, New SV (Response)
In “Operand”, specify the name that indicates the SV classification. Specify the
name in four characters. In “SV”, specify either the word address where the SV is
stored or the constant SV.
Operand
Classification Constant or
ddd
OP1 OP2 OP3 OP4
word address
C I O (S) IR or SR 0000 to 0511
L R (S) (S) LR 0000 to 0063
H R (S) (S) HR 0000 to 0099
A R (S) (S) AR 0000 to 0027
D M (S) (S) DM 0000 to 6655
D M : (S) DM (indirect) 0000 to 6655
C O N (S) Constant 0000 to 9999
(S): Space
11-3-21 STATUS READ –– MS
Reads the PC operating conditions.
Command Format
@ MS
x 10
0
x 10
1
:
Node no. Header
code
TerminatorFCS
Response Format
@ MS
x 16
2
x 10
0
x 10
1
x 16
1
x 16
0
x 16
3
x 16
0
x 16
1
:
Node no. Header
code
Status dataEnd code TerminatorFCS
Message
16 characters
Host Link Commands
Section 11-3